Power, control and grounding cable from 300 V to 230 kV, in copper and aluminum, with accessories.
From the utility line to the load
The eight product families by their place in the power system.
- Medium-voltage power cableSwitchgear to transformers and medium-voltage equipment
- Building wireFeeders and branch circuits in conduit
- Armored and metal-clad cableFeeders and branch circuits without conduit
- Tray, control and instrumentation cableMotors, drives, controls and instruments
- Flexible and portable power cableGenerator, UPS and battery connections
- Bare copper and groundingGround grid and equipment bonding
- High-voltage and utility cableUtility interconnection, 69 kV to 230 kV
- Terminations, splices and accessoriesAt every cable end and joint
Medium-voltage power cable
Shielded power cable, 5 kV to 35 kV, 2 AWG to 1000 kcmil, in copper and aluminum. Single-conductor, three-conductor, armored and underground distribution constructions.
View range- 1/C Type MV-1055, 8, 15, 25, 35 kV
- 3/C Type MV-1055 kV to 35 kV
- 1/C Type MV-905 kV to 35 kV
- Type MV-90, nonshielded2.4 kV
- Type MC, interlocked armor5 kV to 35 kV
- Type MC-HL5 kV to 35 kV
- Primary UD (URD)15, 25, 35 kV
Building wire
600 V and 2 kV single conductors in copper and aluminum for services, feeders and branch circuits.
View range- Type THHN/THWN-2600 V; 90 °C
- Type XHHW-2600 V; 90 °C wet or dry
- Type RHH/RHW-2/USE-2600 V; 90 °C wet or dry
- Type RHH/RHW-22 kV
- Photovoltaic wire, Type PV600 V; 1 kV; 2 kV
- Type TFFN, MTW and SIS600 V
- Type XHHW-2, aluminum600 V; 90 °C wet or dry
- Type RHH/RHW-2/USE-2, aluminum600 V
- Service entrance cable, Type SE600 V
- Secondary UD600 V
- 2-hour fire-rated cable600 V
- Low-smoke zero-halogen600 V to 35 kV
- All 12 types
Armored and metal-clad cable
Type MC and Type MC-HL cable for feeders, branch circuits, control and hazardous locations, 300 V to 35 kV.
View range- Type MC600 V
- Type MC feeder cable600 V
- Type MC, PVC jacketed600 V
- Type MC, steel armor600 V
- Type MC, health care facility (HCF)600 V
- Type AC and AC-HCF600 V
- Type MC-HL power cable600 V; 1 kV
- Type MC-HL control cable600 V
- Type ITC-HL/PLTC instrumentation cable300 V
- Type MC, interlocked armor5 kV to 35 kV
- Type MC-HL5 kV to 35 kV
- All 11 types
Tray, control and instrumentation cable
Multi-conductor power, control, VFD and instrumentation cable for cable tray and exposed runs.
View range- Type TC-ER, XHHW-2 conductors600 V; 90 °C wet or dry
- Type TC-ER, THHN/THWN conductors600 V
- Type TC-ER, EPR/CPE600 V; 2 kV
- VFD cable600 V; 1 kV; 2 kV
- Type TC control cable600 V
- Shielded control cable600 V
- Type PLTC/ITC, overall shield300 V
- Type PLTC/ITC, individual and overall shield300 V
- Type TC instrumentation cable600 V
- Thermocouple extension cable300 V
- Fire alarm cable300 V
- All 11 types
Flexible and portable power cable
Flexible-stranded power cable and cord for generators, UPS and battery systems, switchgear and temporary power.
View range- Type DLO2 kV
- Telecom and DC power cable600 V
- Welding cable600 V
- Type W2 kV
- Type G and G-GC2 kV
- Type SHD-GC5 kV to 25 kV
- Type SOOW and SJOOW600 V; 300 V
Bare copper and grounding
Bare, tinned and insulated grounding conductor for ground grids, counterpoise, equipment bonding and substations.
View range- Bare copper, soft drawn14 AWG to 1000 kcmil
- Bare copper, medium-hard and hard drawn8 AWG to 1000 kcmil
- Tinned copper14 AWG to 500 kcmil
- Copper-clad steel7 No. 9 to 19 No. 5
- Insulated ground14 AWG to 750 kcmil
- Ground rods5/8 in and 3/4 in; 8 ft and 10 ft
- Grounding connectorsTo conductor size
High-voltage and utility cable
Transmission cable systems, overhead conductor, underground distribution and substation cable for interconnection and utility work.
View range- XLPE transmission cable69, 115, 138, 161, 230 kV
- Terminations and joints69 kV to 230 kV
- ACSR6 AWG to 2156 kcmil
- AAC6 AWG to 2000 kcmil
- AAAC6 AWG to 1000 kcmil
- ACSS266.8 kcmil to 2156 kcmil
- Overhead ground wire7 No. 8 AW; 3/8 in and 7/16 in EHS
- Service drop cable600 V
- Primary UD (URD)15, 25, 35 kV
- Secondary UD600 V
- Substation control cable600 V; 1 kV
- Station ground conductor2 AWG to 500 kcmil
- All 12 types
Terminations, splices and accessories
Medium-voltage terminations, splices and separable connectors, compression lugs, cable cleats, glands and pulling accessories.
View range- Terminations5 kV to 35 kV
- Splices5 kV to 35 kV
- Separable connectors15, 25, 35 kV
- Shield grounding kits5 kV to 35 kV
- Compression lugs and connectors600 V to 35 kV
- Cable cleatsTo short-circuit rating
- Cable glands and MC connectors600 V to 35 kV
- Pulling eyes and gripsTo cable size
- Installation materialsTo cable size
- All 9 types